EZ Maintenance CMMS Software Img



background image
different groupings create a source of potential,
the amount of which is indicated by the separation
between the metals on the listing. As shown in
table 1
, the most anodic or "least noble" metals
are at the top of the list, and the most cathodic or
"most noble" metals are at the bottom. It should
be remembered that the series is a guide as to
what can be expected and is not intended to
replace actual experimental tests in assessing
specific problems under consideration.
2.6. Characteristics of soil which affect the
corrosion rates.- Three prime factors that affect
the severity and acceleration of corrosion of
metals in soil are moisture, salt and/or acid
content, and aeration. Corrosion, as mentioned
before, is an electrochemical process. It has been
found that the chemical approach in analyzing soil
corrosiveness is too involved to be practical.
However, a correlation exists between what is
called "soil corrosivity" and "soil electrical
resistivity." Soil moisture in conjunction with
soluble soil salts constitutes the electrolyte of the
corrosion cell and is, therefore, the cell's internal
circuit. Consequently, the higher the resistance of
the soil electrolyte, the lower the rate at which the
corrosion cell functions. The soil resistivity is
especially indicative of soil corrosivity in alkaline
soils and is useful as a guide in acid soils. The
commonly used unit of soil and water resistivity is
the ohm-centimeter, which is the resistance in
ohms of a 1-centimeter cube of the material in
question measured between two opposite,
parallel faces. In considering soil as an
electrolyte, the salt and water content determines
the cell resistance. The moisture content will
normally change radically with seasons. This one
factor alone can give soil resistivity variation from
a minimum of 2500 to a maximum of 10 000 ohm-
centimeters, where extreme dryness occurs.
2.7. Soil resistivity.-In correlating the resistivity
readings obtained with expected corrosion action,
the following soil resistivity values can be used as
a guide:
(a) Values of 1000 ohm-centimeters or
lower indicate very corrosive conditions.
(b) Values from 1000 to 5000 ohm-
centimeters usually indicate moderately
corrosive conditions.
(c) Values from 5,000 to 10,000 ohm-
centimeters indicate mildly corrosive
conditions.
(d) Values above 10,000 ohm-centimeters
indicate slightly corrosive conditions.
Values between the 1,000 and 10,000 ohm-cen-
timeters should be compared to those in im-
mediately adjacent sections of the structure. For
example, if resistivity readings are running at
10,000 ohm-centimeters and there is in a short
distance a drop to 2,000 ohm-centimeters,
corrosion is likely to occur in the 2000-ohm-
centimeter area. These areas of low resistivity are
referred to as "hot spots." Also, changes in high
soil resistivity can sometimes be conducive to
corrosion; for example, a change from 10,000 to
100,000 ohm-centimeters.
2.8. Characteristics of water which affect the
corrosion rates.- The effect of the electrolyte on
the corrosion rate depends on the temperature,
on the dissolved oxygen concentration, and on
the nature and concentration of the dissolved
salts which may or may not tend to make the
water scale forming. The interrelationship of these
factors with respect to corrosion is not fully
understood. Therefore, we do not have firm and
specific criteria for evaluating the corrosion
property of water on the basis of its chemical
characteristics.
2.9. Polarization.- When corrosion occurs,
chemical reactions take place at the electrodes.
These reactions may "plate out" the reaction
products on the electrodes; for instance,
hydrogen ions may be converted to uncharged
hydrogen or calcium ions which ultimately may be
converted to a calcium carbonate scale on the
cathode. Such deposits often act to increase the
electrical resistance of the internal circuit, with the
result that the flow of current and the corrosion
rate are reduced. Opposing chemical reactions
tend to depolarize. For instance, oxygen in the
electrolyte may react with hydrogen to form water.
This reverse reaction tends to negate the
beneficial effects of polarization.
(FIST 4- 5)
4
CMMS Fleet Maintenance Software for Fleet, Vehicle, & Equipment Maintenance

This Information is Reprinted From UNITED STATES DEPARTMENT OF THE INTERIOR BUREAU OF RECLAMATION